It was found that doaproutch function in crypto/bio/bprint.c in OpenSSL 1.0.1 before 1.0.1s and 1.0.2 before 1.0.2g does not verify that a certain memory allocation succeeds, which allows remote attackers to cause a denial of service (out-of-bounds write or memory consumption) or possibly have unspecified other impact via a long string, as demonstrated by a large amount of ASN.1 data. This issues is different than CVE-2016-0799.
Upstream patch:
https://git.openssl.org/?p=openssl.git;a=commit;h=578b956fe741bf8e84055547b1e83c28dd902c73
As per Upstream advisory:
The internal |fmtstr| function used in processing a "%s" format string in the BIOprintf functions could overflow while calculating the length of a string and cause an OOB read when printing very long strings.
Additionally the internal |doaproutch| function can attempt to write to an OOB memory location (at an offset from the NULL pointer) in the event of a memory allocation failure. In 1.0.2 and below this could be caused where the size of a buffer to be allocated is greater than INTMAX. E.g. this could be in processing a very long "%s" format string. Memory leaks can also occur.
These issues will only occur on certain platforms where sizeof(sizet) > sizeof(int). E.g. many 64 bit systems. The first issue may mask the second issue dependent on compiler behaviour. These problems could enable attacks where large amounts of untrusted data is passed to the BIOprintf functions. If applications use these functions in this way then they could be vulnerable. OpenSSL itself uses these functions when printing out human-readable dumps of ASN.1 data. Therefore applications that print this data could be vulnerable if the data is from untrusted sources. OpenSSL command line applications could also be vulnerable where they print out ASN.1 data, or if untrusted data is passed as command line arguments.
Libssl is not considered directly vulnerable. Additionally certificates etc received via remote connections via libssl are also unlikely to be able to trigger these issues because of message size limits enforced within libssl.
This issue affects OpenSSL versions 1.0.2 and 1.0.1.
OpenSSL 1.0.2 users should upgrade to 1.0.2g OpenSSL 1.0.1 users should upgrade to 1.0.1s
This issue was reported to OpenSSL on February 23rd by Guido Vranken. The fix was developed by Matt Caswell of the OpenSSL development team.
Advantech iView versions prior to v5.7.04 build 6425 contain a vulnerability within the SNMP management tool that allows for remote attackers to bypass authentication checks and reach a SQL injection vulnerability within the ‘searchterm’ parameter to the ‘NetworkServlet’ endpoint. Successful exploitation allows for remote code execution with administrator privileges.
Advantech iView versions prior to v5.7.04 build 6425 contain a vulnerability within the SNMP management tool that allows for remote attackers to bypass authentication checks and reach a SQL injection vulnerability within the ‘ztpsearchvalue’ parameter to the ‘NetworkServlet’ endpoint. Successful exploitation allows for remote code execution with administrator privileges.
Path Traversal in DIAEnergie.
This issue affects DIAEnergie: before 1.11.00.022.
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the edgserver management service of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a remote unauthenticated attacker to execute arbitrary OS commands as root via crafted requests to TCP port 5058.
Advantech WISE-DeviceOn Server versions prior to 5.4 contain a hard-coded cryptographic key vulnerability. The product uses a static HS512 HMAC secret for signing EIRMMToken JWTs across all installations. The server accepts forged JWTs that need only contain a valid email claim, allowing a remote unauthenticated attacker to generate arbitrary tokens and impersonate any DeviceOn account, including the root super admin. Successful exploitation permits full administrative control of the DeviceOn instance and can be leveraged to execute code on managed agents through DeviceOn’s remote management features.
Hospital Queuing Management developed by Advantech has a Sensitive Data Exposure vulnerability, allowing unauthenticated remote attackers to access a specific URL to obtain API documentation.
A stack-based buffer overflow vulnerability in Advantech WebAccess Versions 9.02 and prior caused by a lack of proper validation of the length of user-supplied data may allow remote code execution.
In Advantech WebAccess versions V8.220170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a heap-based buffer overflow vulnerability has been identified, which may allow an attacker to execute arbitrary code.
In Advantech WebAccess versions V8.220170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a TFTP application has unrestricted file uploads to the web application without authorization, which may allow an attacker to execute arbitrary code.
In Advantech WebAccess versions V8.220170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, several stack-based buffer overflow vulnerabilities have been identified, which may allow an attacker to execute arbitrary code.
In Advantech WebAccess versions V8.220170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, several untrusted pointer dereference vulnerabilities have been identified, which may allow an attacker to execute arbitrary code.
The VBWinExec function in Node\AspVBObj.dll in Advantech WebAccess 8.3.0 allows remote attackers to execute arbitrary OS commands via a single argument (aka the command parameter).
An issue was discovered in Advantech WebAccess Version 8.1. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access pages unrestricted (AUTHENTICATION BYPASS).
An issue was discovered in Advantech WebAccess Version 8.1. To be able to exploit the SQL injection vulnerability, an attacker must supply malformed input to the WebAccess software. Successful attack could result in administrative access to the application and its data files.
The Advantech ADAM-6000 module has 00000000 as its default password, which makes it easier for remote attackers to obtain access through an HTTP session, and (1) monitor or (2) control the module's Modbus/TCP I/O activity.
Successful exploitation of the SQL injection vulnerability could allow an unauthenticated remote attacker to execute arbitrary SQL commands on the vulnerable service when it is exposed to the Internet, potentially affecting data confidentiality, integrity, and availability. Users and administrators of affected product versions are advised to update to the latest versions immediately.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "cfgcmdsetethconf" operation.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "wlanscan" operation.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backupconfigtoutility" operation.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restoreconfigfromutility" operation.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capturepackages" operation.
A CWE-306 "Missing Authentication for Critical Function" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point.
Advantech WebAccess/SCADA is vulnerable to directory traversal, which may allow an attacker to delete arbitrary files.
Advantech iView versions prior to v5.7.04 build 6425 contain a vulnerability within the SNMP management tool that allows for remote attackers to bypass authentication checks and reach a SQL injection vulnerability within the ‘getInventoryReportData’ parameter to the ‘NetworkServlet’ endpoint. Successful exploitation allows for remote code execution with administrator privileges.
upAdminPg.asp in Advantech WebAccess before 7.2 allows remote authenticated users to discover credentials by reading HTML source code.
Successful exploitation of the vulnerability could allow an unauthenticated attacker to upload firmware through a public update page, potentially leading to backdoor installation or privilege escalation.
The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions.
The affected product is vulnerable to directory traversal, which may allow an attacker to access unauthorized files and execute arbitrary code.