Where
-Infinity
0
Severity
7.5
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

The Contec Co.,Ltd. CONPROSYS HMI System (CHS) exposes a PHP phpinfo() debug page to unauthenticated users that may contain sensitive data useful for an attacker.This issue affects CONPROSYS HMI System (CHS): before 3.7.7.

First published (updated )
Severity
6.1
XSS
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

The Contec Co.,Ltd. CONPROSYS HMI System (CHS) is vulnerable to Cross-Site Scripting (XSS) in the getqsetting.php functionality that could allow reflected execution of scripts in the browser on interaction.This issue affects CONPROSYS HMI System (CHS): before 3.7.7.

First published (updated )
Severity
7.7
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

The "monitor" binary in the firmware of the affected product attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function also enables the network interface of the device if it is disabled. The function is triggered by attempting to update the device from the user menu. This could serve as a backdoor to the device, and could lead to a malicious actor being able to upload and overwrite files on the device.

Remedy

Per FDA recommendation, CISA recommends users remove any Contec CMS8000 devices from their networks. Please note that this device may be re-labeled and sold by resellers. For a list of known re-labeled devices, please refer to FDA's safety communication https://www.fda.gov/medical-devices/safety-communications/cybersecurity-vulnerabilities-certain-patient-monitors-contec-and-epsimed-fda-safety-communication .
First published (updated )
Severity
9.8
Code Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An issue in Contec SolarView Compact v.6.0 and before allows an attacker to execute arbitrary code via the texteditor.php component.

First published (updated )
Severity
7.5
Path Traversal
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

SolarView Compact < 6.00 is vulnerable to Directory Traversal.

First published (updated )
Severity
4.9
SSRF
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N

Server-side request forgery vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may bypass the database restriction set on the query setting page, and connect to a user unintended database.

First published (updated )
Severity
8.1
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N

Plaintext storage of a password exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. Because account information of the database is saved in a local file in plaintext, a user who can access the PC where the affected product is installed can obtain the information. As a result, information in the database may be obtained and/or altered by the user.

First published (updated )
Severity
8.8
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Improper access control vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user of the PC where the affected product is installed may gain an administrative privilege. As a result, information regarding the product may be obtained and/or altered by the user.

First published (updated )
Severity
7.2
SQL Injection
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

SQL injection vulnerability exists in the CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may execute an arbitrary SQL command via specially crafted input to the query setting page.

First published (updated )
Severity
7.8
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Incorrect permission assignment for critical resource exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. ACL (Access Control List) is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC where the affected product is installed. As a result, the user may be able to destroy the system and/or execute a malicious program.

First published (updated )
Severity
4.8
XSS
CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N

Cross-site scripting vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. If a user who can access the affected product with an administrative privilege configures specially crafted settings, an arbitrary script may be executed on the web browser of the other user who is accessing the affected product with an administrative privilege.

First published (updated )
Severity
5.3
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L

A denial of service vulnerability exists in Contec CONPROSYS HMI System versions 3.5.2 and prior. When there is a time-zone mismatch in certain configuration files, a remote, unauthenticated attacker may deny logins for an extended period of time.

First published (updated )
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

SolarView Compact <= 6.0 is vulnerable to Insecure Permissions. Any file on the server can be read or modified because texteditor.php is not restricted.

First published (updated )
Severity
4.3
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N

Improper access control vulnerability in the system date/time setting page of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F versions prior to Ver.8.10 allows a remote authenticated attacker to alter system date/time of the affected product.

First published (updated )
Severity
8.8
Command Injection, OS Command Injection
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

OS command injection vulnerability in the download page of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F versions prior to Ver.8.10 allows a remote authenticated attacker to execute an arbitrary OS command.

First published (updated )
Severity
7.2
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Use of hard-coded credentials exists in SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10, and SV-CPT-MC310F versions prior to Ver.8.10, which may allow a remote authenticated attacker to login the affected product with an administrative privilege and perform an unintended operation.

First published (updated )
Severity
8.8
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Buffer overflow vulnerability in the multiple setting pages of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F versions prior to Ver.8.10 allows a remote authenticated attacker to execute arbitrary code.

First published (updated )
Severity
8.8
Command Injection, OS Command Injection
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

OS command injection vulnerability in the mail setting page of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F versions prior to Ver.8.10 allows remote authenticated attackers to execute an arbitrary OS command.

First published (updated )
Severity
7.2
Weak Encryption
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Inadequate encryption strength vulnerability in CONPROSYS IoT Gateway products allows a remote authenticated attacker with an administrative privilege to apply a specially crafted Firmware update file, alter the information, cause a denial-of-service (DoS) condition, and/or execute arbitrary code. The affected products and versions are as follows: M2M Gateway with the firmware Ver.3.7.10 and earlier (CPS-MG341-ADSC1-111, CPS-MG341-ADSC1-931, CPS-MG341G-ADSC1-111, CPS-MG341G-ADSC1-930, and CPS-MG341G5-ADSC1-931), M2M Controller Integrated Type with firmware Ver.3.7.6 and earlier versions (CPS-MC341-ADSC1-111, CPS-MC341-ADSC1-931, CPS-MC341-ADSC2-111, CPS-MC341G-ADSC1-110, CPS-MC341Q-ADSC1-111, CPS-MC341-DS1-111, CPS-MC341-DS11-111, CPS-MC341-DS2-911, and CPS-MC341-A1-111), and M2M Controller Configurable Type with firmware Ver.3.8.8 and earlier versions (CPS-MCS341-DS1-111, CPS-MCS341-DS1-131, CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130, and CPS-MCS341Q-DS1-131).

First published (updated )
Severity
8.8
Command Injection, OS Command Injection
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

OS command injection vulnerability in CONPROSYS IoT Gateway products allows a remote authenticated attacker who can access Network Maintenance page to execute arbitrary OS commands with a root privilege. The affected products and versions are as follows: M2M Gateway with the firmware Ver.3.7.10 and earlier (CPS-MG341-ADSC1-111, CPS-MG341-ADSC1-931, CPS-MG341G-ADSC1-111, CPS-MG341G-ADSC1-930, and CPS-MG341G5-ADSC1-931), M2M Controller Integrated Type with firmware Ver.3.7.6 and earlier versions (CPS-MC341-ADSC1-111, CPS-MC341-ADSC1-931, CPS-MC341-ADSC2-111, CPS-MC341G-ADSC1-110, CPS-MC341Q-ADSC1-111, CPS-MC341-DS1-111, CPS-MC341-DS11-111, CPS-MC341-DS2-911, and CPS-MC341-A1-111), and M2M Controller Configurable Type with firmware Ver.3.8.8 and earlier versions (CPS-MCS341-DS1-111, CPS-MCS341-DS1-131, CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130, and CPS-MCS341Q-DS1-131).

First published (updated )
Severity
4.3
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N

Improper access control vulnerability in CONPROSYS IoT Gateway products allows a remote authenticated attacker to bypass access restriction and access Network Maintenance page, which may result in obtaining the network information of the product. The affected products and versions are as follows: M2M Gateway with the firmware Ver.3.7.10 and earlier (CPS-MG341-ADSC1-111, CPS-MG341-ADSC1-931, CPS-MG341G-ADSC1-111, CPS-MG341G-ADSC1-930, and CPS-MG341G5-ADSC1-931), M2M Controller Integrated Type with firmware Ver.3.7.6 and earlier versions (CPS-MC341-ADSC1-111, CPS-MC341-ADSC1-931, CPS-MC341-ADSC2-111, CPS-MC341G-ADSC1-110, CPS-MC341Q-ADSC1-111, CPS-MC341-DS1-111, CPS-MC341-DS11-111, CPS-MC341-DS2-911, and CPS-MC341-A1-111), and M2M Controller Configurable Type with firmware Ver.3.8.8 and earlier versions (CPS-MCS341-DS1-111, CPS-MCS341-DS1-131, CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130, and CPS-MCS341Q-DS1-131).

First published (updated )
Severity
9.8
Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

There is a command injection vulnerability in SolarView Compact through 6.00, attackers can execute commands by bypassing internal restrictions through downloader.php.

First published (updated )
Severity
6.5
SQL Injection
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

SQL injection vulnerability in the CONPROSYS HMI System (CHS) Ver.3.5.0 and earlier allows a remote authenticated attacker to execute an arbitrary SQL command. As a result, information stored in the database may be obtained.

First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

Use of default credentials vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote unauthenticated attacker to alter user credentials information.

First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Improper access control vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote unauthenticated attacker to bypass access restriction and obtain the server certificate including the private key of the product.

First published (updated )
Severity
5.7
XSS
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N

Cross-site scripting vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote authenticated attacker to inject an arbitrary script and obtain the sensitive information.

First published (updated )
Severity
5.3
CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N

Use of password hash instead of password for authentication vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote authenticated attacker to obtain user credentials information via a man-in-the-middle attack.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.