Where
-Infinity
0
Severity
8.7
OS Command Injection, Command Injection
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Contec FX5000 series, FX4000 series, and FX3000 series. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product.

First published (updated )
Severity
5.3
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L

Stack-based buffer overflow vulnerability exists in Remote I/O Coupler Unit (Server Type) CPSN-MCB271-. Receiving a specially crafted request created and sent by a remote attacker may cause a denial-of-service (DoS) condition.

First published (updated )
Severity
5.1
CSRF
AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N

Cross-site request forgery vulnerability exists in multiple Contec products. If a user views a specially crafted page while logged in to the affected product, unintended operations may be performed.

First published (updated )
Severity
8.7
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Buffer overflow vulnerability exists in Contec EC1000 series. If a remote attacker sends a specially crafted request to the product's web service, an arbitrary program may be executed.

First published (updated )
Severity
8.2
AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N

Insufficiently protected credentials issue exists in Remote I/O Coupler Unit (Server Type) CPSN-MCB271-. If this vulnerability is exploited, sensitive information may be restored from a backup file.

First published (updated )
Severity
9.8
Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

SolarView Compact 6.00 was discovered to contain a command injection vulnerability via networktest.php

First published (updated )
Severity
9.8
Command Injection, OS Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

SolarView Compact contains a command injection vulnerability due to improper validation of input values on the send test mail console of the product's web server.

1 / 2
Source: CISA
First published (updated )
Severity
5
Path Traversal
AV:N/AC:L/Au:N/C:P/I:N/A:N

Multiple directory traversal vulnerabilities in (1) modevhost and (2) modsimplevhost in lighttpd before 1.4.35 allow remote attackers to read arbitrary files via a .. (dot dot) in the host name, related to requestcheckhostname.

First published (updated )
Severity
6.1
XSS
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

The Contec Co.,Ltd. CONPROSYS HMI System (CHS) is vulnerable to Cross-Site Scripting (XSS) in the getqsetting.php functionality that could allow reflected execution of scripts in the browser on interaction.This issue affects CONPROSYS HMI System (CHS): before 3.7.7.

First published (updated )
Severity
7.5
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

The Contec Co.,Ltd. CONPROSYS HMI System (CHS) exposes a PHP phpinfo() debug page to unauthenticated users that may contain sensitive data useful for an attacker.This issue affects CONPROSYS HMI System (CHS): before 3.7.7.

First published (updated )
Severity
8.8
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Contec FXA3200 version 1.13 and under were discovered to contain a hard coded hash password for root stored in the component /etc/shadow. As the password strength is weak, it can be cracked in few minutes. Through this credential, a malicious actor can access the Wireless LAN Manager interface and open the telnet port then sniff the traffic or inject any malware.

First published (updated )
Severity
8.8
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Contec FXA3200 version 1.13.00 and under suffers from Insecure Permissions in the Wireless LAN Manager interface which allows malicious actors to execute Linux commands with root privilege via a hidden web page (/usr/www/ja/mntcmd.cgi).

First published (updated )
Severity
9.8
Malicious File Upload
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

SolarView Compact 4.0 and 5.0 is vulnerable to Unrestricted File Upload via a crafted php file.

First published (updated )
Severity
6.1
XSS
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

SolarView Compact 7.0 is vulnerable to Cross-site Scripting (XSS) via /networktest.php.

First published (updated )
Severity
10
OS Command Injection, Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

CONPROSYS HMI System (CHS) Ver.3.4.4?and earlier allows a remote unauthenticated attacker to execute an arbitrary OS command on the server where the product is running by sending a specially crafted request.

First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Improper access control vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote unauthenticated attacker to bypass access restriction and obtain the server certificate including the private key of the product.

First published (updated )
Severity
5.7
XSS
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N

Cross-site scripting vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote authenticated attacker to inject an arbitrary script and obtain the sensitive information.

First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

Use of default credentials vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote unauthenticated attacker to alter user credentials information.

First published (updated )
Severity
5.3
CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N

Use of password hash instead of password for authentication vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote authenticated attacker to obtain user credentials information via a man-in-the-middle attack.

First published (updated )
Severity
6.5
SQL Injection
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

SQL injection vulnerability in the CONPROSYS HMI System (CHS) Ver.3.5.0 and earlier allows a remote authenticated attacker to execute an arbitrary SQL command. As a result, information stored in the database may be obtained.

First published (updated )
Severity
9.8
Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

There is a command injection vulnerability in SolarView Compact through 6.00, attackers can execute commands by bypassing internal restrictions through downloader.php.

First published (updated )
Severity
7.7
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

The "monitor" binary in the firmware of the affected product attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function also enables the network interface of the device if it is disabled. The function is triggered by attempting to update the device from the user menu. This could serve as a backdoor to the device, and could lead to a malicious actor being able to upload and overwrite files on the device.

Remedy

Per FDA recommendation, CISA recommends users remove any Contec CMS8000 devices from their networks. Please note that this device may be re-labeled and sold by resellers. For a list of known re-labeled devices, please refer to FDA's safety communication https://www.fda.gov/medical-devices/safety-communications/cybersecurity-vulnerabilities-certain-patient-monitors-contec-and-epsimed-fda-safety-communication .
First published (updated )
Severity
4.3
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N

Improper access control vulnerability in CONPROSYS IoT Gateway products allows a remote authenticated attacker to bypass access restriction and access Network Maintenance page, which may result in obtaining the network information of the product. The affected products and versions are as follows: M2M Gateway with the firmware Ver.3.7.10 and earlier (CPS-MG341-ADSC1-111, CPS-MG341-ADSC1-931, CPS-MG341G-ADSC1-111, CPS-MG341G-ADSC1-930, and CPS-MG341G5-ADSC1-931), M2M Controller Integrated Type with firmware Ver.3.7.6 and earlier versions (CPS-MC341-ADSC1-111, CPS-MC341-ADSC1-931, CPS-MC341-ADSC2-111, CPS-MC341G-ADSC1-110, CPS-MC341Q-ADSC1-111, CPS-MC341-DS1-111, CPS-MC341-DS11-111, CPS-MC341-DS2-911, and CPS-MC341-A1-111), and M2M Controller Configurable Type with firmware Ver.3.8.8 and earlier versions (CPS-MCS341-DS1-111, CPS-MCS341-DS1-131, CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130, and CPS-MCS341Q-DS1-131).

First published (updated )
Severity
8.8
Command Injection, OS Command Injection
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

OS command injection vulnerability in CONPROSYS IoT Gateway products allows a remote authenticated attacker who can access Network Maintenance page to execute arbitrary OS commands with a root privilege. The affected products and versions are as follows: M2M Gateway with the firmware Ver.3.7.10 and earlier (CPS-MG341-ADSC1-111, CPS-MG341-ADSC1-931, CPS-MG341G-ADSC1-111, CPS-MG341G-ADSC1-930, and CPS-MG341G5-ADSC1-931), M2M Controller Integrated Type with firmware Ver.3.7.6 and earlier versions (CPS-MC341-ADSC1-111, CPS-MC341-ADSC1-931, CPS-MC341-ADSC2-111, CPS-MC341G-ADSC1-110, CPS-MC341Q-ADSC1-111, CPS-MC341-DS1-111, CPS-MC341-DS11-111, CPS-MC341-DS2-911, and CPS-MC341-A1-111), and M2M Controller Configurable Type with firmware Ver.3.8.8 and earlier versions (CPS-MCS341-DS1-111, CPS-MCS341-DS1-131, CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130, and CPS-MCS341Q-DS1-131).

First published (updated )
Severity
7.2
Weak Encryption
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Inadequate encryption strength vulnerability in CONPROSYS IoT Gateway products allows a remote authenticated attacker with an administrative privilege to apply a specially crafted Firmware update file, alter the information, cause a denial-of-service (DoS) condition, and/or execute arbitrary code. The affected products and versions are as follows: M2M Gateway with the firmware Ver.3.7.10 and earlier (CPS-MG341-ADSC1-111, CPS-MG341-ADSC1-931, CPS-MG341G-ADSC1-111, CPS-MG341G-ADSC1-930, and CPS-MG341G5-ADSC1-931), M2M Controller Integrated Type with firmware Ver.3.7.6 and earlier versions (CPS-MC341-ADSC1-111, CPS-MC341-ADSC1-931, CPS-MC341-ADSC2-111, CPS-MC341G-ADSC1-110, CPS-MC341Q-ADSC1-111, CPS-MC341-DS1-111, CPS-MC341-DS11-111, CPS-MC341-DS2-911, and CPS-MC341-A1-111), and M2M Controller Configurable Type with firmware Ver.3.8.8 and earlier versions (CPS-MCS341-DS1-111, CPS-MCS341-DS1-131, CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130, and CPS-MCS341Q-DS1-131).

First published (updated )
Severity
8.8
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Buffer overflow vulnerability in the multiple setting pages of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F versions prior to Ver.8.10 allows a remote authenticated attacker to execute arbitrary code.

First published (updated )
Severity
4.3
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N

Improper access control vulnerability in the system date/time setting page of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F versions prior to Ver.8.10 allows a remote authenticated attacker to alter system date/time of the affected product.

First published (updated )
Severity
8.8
Command Injection, OS Command Injection
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

OS command injection vulnerability in the mail setting page of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F versions prior to Ver.8.10 allows remote authenticated attackers to execute an arbitrary OS command.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.