See how honeywell compares to other vendors in security performance
Honeywell Control Network Module (CNM) contains insertion of sensitive information into an unintended directory. An attacker could exploit this vulnerability through probing system files, potentially resulting in unintended access to protected data.
Honeywell recommends updating to the most recent version of this product, service or offering [200.1]. The CNM versions affected are from [100.1, 101.1, 110.1, and 110.2].
Honeywell Control Network Module (CNM) contains command injection vulnerability in the web interface. An attacker could exploit this vulnerability via command delimiters, potentially resulting in Remote Code Execution (RCE).
Honeywell recommends updating to the most recent version of this product, service or offering [200.1]. The CNM versions affected are from [100.1, 101.1, 110.1, and 110.2].
Honeywell S35 Series 3M/5M/8M/PinHole Cameras, all versions prior to and including version HC5.26.1.14.20260207 contains an audit log disclosure Vulnerability that could allow an attacker to access audit logs without authentication, potentially resulting in the disclosure of sensitive information. Honeywell recommends updating to the latest available version (HC5.26.1.16.20260207) once available.
Missing Authentication for Critical Function vulnerability in Honeywell Handheld Scanners allows Authentication Abuse.This issue affects Handheld Scanners: from C1 Base(Ingenic x1000) before GK000432BAA, from D1 Base(Ingenic x1600) before HE000085BAA, from A1/B1 Base(IMX25) before BK000763BAABK000765BAACU000101BAA.
This vulnerability could allow a remote attacker within Bluetooth range of the scanner's base station has the capability to remotely execute system commands on the host connected to the base station without authentication. This issue has been assigned CVE-2026-4272 https://nvd.nist.gov/vuln/detail/CVE-2026-4272 and rated with a severity of High. Honeywell strongly recommends that users upgrade to the latest version identified to resolve the vulnerability.
Honeywell IQ MultiAccess, all versions prior to and including version 28, contain an improper digital signature verification vulnerability. An attacker could potentially exploit this vulnerability, leading to the replacement of downloaded file with a malicious one. Honeywell also recommends updating to the most recent version of this product, service, or offering [V27 SP1, V28 SP1]
Uncontrolled Resource Consumption vulnerability in Honeywell Niagara Framework on Windows, Linux, QNX allows Content Spoofing.This issue affects Niagara Framework: before Niagara AX 3.8.1, before Niagara 4.1.
UNSUPPORTED WHEN ASSIGNED [An attacker can capture an authenticating hash and utilize it to create new sessions. The hash is also a poorly salted MD5 hash, which could result in a successful brute force password attack. Impacted product is BCM-WEB version 3.3.X. Recommended fix: Upgrade to a supported product such as Alerton ACM.] Out of an abundance of caution, this CVE ID is being assigned to better serve our customers and ensure all who are still running this product understand that the product is end of life and should be removed or upgraded.
In Honeywell WIN-PAK 4.7.2, Web and prior versions, the affected product is vulnerable to a cross-site request forgery, which may allow an attacker to remotely execute arbitrary code.
In Honeywell WIN-PAK 4.7.2, Web and prior versions, the affected product is vulnerable due to the usage of old jQuery libraries.
In Honeywell WIN-PAK 4.7.2, Web and prior versions, the header injection vulnerability has been identified, which may allow remote code execution.
In Notifier Web Server (NWS) Version 3.50 and earlier, the Honeywell Fire Web Server’s authentication may be bypassed by a capture-replay attack from a web browser.
Honeywell Notifier Web Server (NWS) Version 3.50 is vulnerable to a path traversal attack, which allows an attacker to bypass access to restricted directories. Honeywell has released a firmware update to address the problem.
Honeywell INNCOM INNControl 3 allows workstation users to escalate application user privileges through the modification of local configuration files.
The following versions of MAXPRO VMS and NVR, MAXPRO VMS:HNMSWVMS prior to Version VMS560 Build 595 T2-Patch, HNMSWVMSLT prior to Version VMS560 Build 595 T2-Patch, MAXPRO NVR: MAXPRO NVR XE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR SE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR PE prior to Version NVR 5.6 Build 595 T2-Patch, and MPNVRSWXX prior to Version NVR 5.6 Build 595 T2-Patch are vulnerable to an unsafe deserialization of untrusted data. An attacker may be able to remotely modify deserialized data without authentication using a specially crafted web request, resulting in remote code execution.
The following versions of MAXPRO VMS and NVR, MAXPRO VMS:HNMSWVMS prior to Version VMS560 Build 595 T2-Patch, HNMSWVMSLT prior to Version VMS560 Build 595 T2-Patch, MAXPRO NVR: MAXPRO NVR XE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR SE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR PE prior to Version NVR 5.6 Build 595 T2-Patch, and MPNVRSWXX prior to Version NVR 5.6 Build 595 T2-Patch contain an SQL injection vulnerability that could give an attacker remote unauthenticated access to the web user interface with administrator-level privileges.
Honeywell MatrikonOPC OPC Controller before 5.1.0.0 allows local users to transfer arbitrary files from a host computer and consequently obtain sensitive information via vectors related to MSXML libraries.
Honeywell Intermec PM23, PM42, PM43, PC23, PC43, PD43, and PC42 industrial printers before 10.11.013310 and 10.12.x before 10.12.013309 have /usr/bin/lua installed setuid to the itadmin account, which allows local users to conduct a BusyBox jailbreak attack and obtain root privileges by overwriting the /etc/shadow file.
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. A user with low privileges is able to open and change the parameters by accessing a specific URL because of Improper Privilege Management.
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. Any user is able to disclose a password by accessing a specific URL, because of Plaintext Storage of a Password.
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. A user without authenticating can make a directory traversal attack by accessing a specific URL.
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. An attacker can establish a new user session, without invalidating any existing session identifier, which gives the opportunity to steal authenticated sessions (SESSION FIXATION).
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. Password is stored in clear text.
The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration.
An issue was discovered in Honeywell Experion Process Knowledge System (PKS) platform: Experion PKS, Release 3xx and prior, Experion PKS, Release 400, Experion PKS, Release 410, Experion PKS, Release 430, and Experion PKS, Release 431. Experion PKS does not properly validate input. By sending a specially crafted packet, an attacker could cause the process to terminate. A successful exploit would prevent firmware uploads to the Series-C devices.
C300 information leak due to an analysis feature which allows extracting more memory over the network than required by the function. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
Server receiving a malformed message that where the GCL message hostname may be too large which may cause a stack overflow; resulting in possible remote code execution. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
Server receiving a malformed message based on a list of IPs resulting in heap corruption causing a denial of service. See Honeywell Security Notification for recommendations on upgrading and versioning.
Server information leak for the CDA Server process memory can occur when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning.
Server receiving a malformed message based on a using the specified key values can cause a stack overflow vulnerability which could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification for recommendations on upgrading and versioning.
Authorization bypass can be achieved by session ID prediction in MASmobile Classic Android version 1.16.18 and earlier and
MASmobile Classic iOS version 1.7.24 and earlier
which allows remote attackers to retrieve sensitive data including customer data, security system status, and event history.