Where
-Infinity
0

Vendor Risk Score

See how mitsubishi electric compares to other vendors in security performance

View Risk Score →

Software

mitsubishi electric gx works3
18
mitsubishi electric mc works64
14
mitsubishi electric genesis64
11
mitsubishi electric gx works2
11
mitsubishi electric 1.000a to 1.011m
9
mitsubishi electric 1.015r to 1.087r (affected by cve-2022-25164, cve-2022-29825, cve-2022-29826, cve-2022-29827, cve-2022-29828, cve-2022-29829, cve-2022-29830, cve-2022-29831, cve-2022-29832, cve-2022-29833)
9
mitsubishi electric 1.090u (affected by cve-2022-25164, cve-2022-29825, cve-2022-29827, cve-2022-29828, cve-2022-29829, cve-2022-29830, cve-2022-29831, cve-2022-29832, cve-2022-29833)  --------- begin update b part 1 of 2 ---------
9
mitsubishi electric 1.095z
9
mitsubishi electric 1.096a
9
mitsubishi electric gt designer3 version1 (got2000)
9
mitsubishi electric cw configurator
8
mitsubishi electric ezsocket
8
mitsubishi electric fr configurator2
8
mitsubishi electric gt softgot2000
8
mitsubishi electric gx works3:   1.000a to 1.011m (affected by cve-2022-25164, cve-2022-29825, cve-2022-29826, cve-2022-29827, cve-2022-29828, cve-2022-29829, cve-2022-29830)  1.015r to 1.087r (affected by cve-2022-25164, cve-2022-29825, cve-2022-29826, cve-2022-29827, cve-2022-29828, cve-2022-29829, cve-2022-29830, cve-2022-29831, cve-2022-29832, cve-2022-29833) 1.090u (affected by cve-2022-25164, cve-2022-29825, cve-2022-29827, cve-2022-29828, cve-2022-29829, cve-2022-29830, cve-2022-29831, cve-2022-29832, cve-2022-29833)  --------- begin update b part 1 of 2 ---------  1.095z (affected by cve-2022-25164, cve-2022-29827, cve-2022-29828, cve-2022-29830, cve-2022-29831, cve-2022-29832, cve-2022-29833)  1.096a and later (affected by cve-2022-29827, cve-2022-29828, cve-2022-29832, cve-2022-29833)
8
mitsubishi electric iconics suite
8
mitsubishi electric iq works (melsoft navigator)
8
mitsubishi electric gt1450-qlbde
7
mitsubishi electric gt1450-qmbde
7
mitsubishi electric gt1450hs-qmbde
7
mitsubishi electric gt1455-qtbde
7
mitsubishi electric gt1455hs-qtbde
7
mitsubishi electric mobilehmi
7
mitsubishi electric mx opc ua module configurator-r
7
mitsubishi electric cpu module logging configuration tool
6
mitsubishi electric data transfer
6
mitsubishi electric fx5uc-32mr/ds-ts
6
mitsubishi electric fx5uc-32mt/d firmware
6
mitsubishi electric fx5uc-32mt/ds-ts
6
mitsubishi electric fx5uc-32mt/ds-ts firmware
6
mitsubishi electric fx5uc-32mt/dss
6
mitsubishi electric fx5uc-32mt/dss firmware
6
mitsubishi electric fx5uc-32mt/dss-ts
6
mitsubishi electric fx5uc-32mt/dss-ts firmware
6
mitsubishi electric fx5uj-24mr/es
6
mitsubishi electric fx5uj-24mt/es
6
mitsubishi electric fx5uj-24mt/es firmware
6
mitsubishi electric fx5uj-24mt/ess firmware
6
mitsubishi electric fx5uj-40mr/es
6
mitsubishi electric fx5uj-40mr/es firmware
6
mitsubishi electric fx5uj-40mt/es
6
mitsubishi electric fx5uj-40mt/es firmware
6
mitsubishi electric fx5uj-40mt/ess
6
mitsubishi electric fx5uj-60mr/es
6
mitsubishi electric fx5uj-60mr/es firmware
6
mitsubishi electric fx5uj-60mt/ess
6
mitsubishi electric fx5uj-60mt/ess firmware
6
mitsubishi electric hyper historian
6
mitsubishi electric melsec iq-f fx5uj cpu modules
6
mitsubishi electric fr configurator2 firmware
5
Severity
5.9
AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H

Improper Validation of Specified Index, Position, or Offset in Input vulnerability in Mitsubishi Electric CNC M800V Series M800VW and M800VS, M80V Series M80V and M80VW, M800 Series M800W and M800S, M80 Series M80 and M80W, E80 Series E80, C80 Series C80, and M700V Series M750VW, M720VW, 730VW, M720VS, M730VS, and M750VS, M70V Series M70V, E70 Series E70 allows a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition by sending specially crafted packets to TCP port 683.

First published (updated )
Severity
7.5
EPSS
0.07%
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Series CC-Link IE TSN Master/Local Module, MELSEC iQ-R Series Ethernet Interface Module, CC-Link IE TSN Master/Local Station Communication LSI CP610, MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module, MELSEC iQ-F Series FX5 Ethernet Module, MELSEC iQ-F Series FX5-ENET/IP Ethernet Module, and MELSEC iQ-R Series CPU module allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets.

First published (updated )
Severity
7.1
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Mitsubishi Electric MELSEC MX Controller MX-R model, MELSEC MX Controller MX-F model, Master/local module, CC-Link IE TSN interface board, Motion module, Motion Control Board, Block-type remote module, Block-type remote module with safety functions, Analog-Digital converter module, Digital-Analog converter module, CC-Link IE TSN compatible coupler, FPGA module, Tension meter, AC Servo MELSERVO-J5, AC Servo MELSERVO-JET, Liner Track System MTR-S series Linear track control module, Inverter FR-A800/F800/E800 Series, Industrial Robot CR800-D series controller Network Base Card, CC-Link IE TSN expansion unit, CC-Link IE TSN-CC-Link IE Field Network bridge module, CC-Link IE TSN-AnyWireASLINK bridge module, Energy Measuring Unit CC-Link IE TSN Communication Unit, Industrial Computer MELIPC series, GOT3000 Series, CC-Link IE TSN Communication Unit, Motion Control Software, CC-Link IE TSN Communication Software for Windows, Analysis Support Software MELSOFT VIMA, Master/Local module Designated communication LSI DeviceKit, Master/Local module Designated communication LSI, Remote Station Communication LSI with GbE-PHY, CC-Link IE TSN Master/Local module Designated communication LSI SDK, and Remote station software development kit allows an attacker with access to a CC-Link IE TSN network to tamper with communication data (control input/output values) by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly.

First published (updated )
Severity
9.3
SQL Injection
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric GENESIS versions 11.02 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS versions 11.02 and prior allows a local attacker to disclose the SQL Server credentials stored in plaintext within the local SQLite file by exploiting this vulnerability, when the local caching feature using SQLite is enabled and SQL authentication is used for the SQL Server authentication. As a result, the unauthorized attacker could access the SQL Server and disclose, tamper with, or destroy data on the server, potentially cause a denial-of-service (DoS) condition on the system.

First published (updated )
Severity
9.3
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Cleartext Storage of Sensitive Information in GUI vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric GENESIS versions 11.02 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS versions 11.02 and prior allows a local attacker to disclose the SQL Server credentials displayed in plain text in the GUI of the Hyper Historian Splitter feature by exploiting this vulnerability, when SQL authentication is used for the SQL Server authentication. As a result, the unauthorized attacker could access the SQL Server and disclose, tamper with, or destroy data on the server, potentially cause a denial-of-service (DoS) condition on the system.

First published (updated )
Severity
8.7
EPSS
0.64%
Integer Overflow
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Integer Overflow or Wraparound vulnerability in the EtherNet/IP function of Mitsubishi Electric MELSEC iQ-F Series FX5-EIP EtherNet/IP module FX5-EIP versions 1.000 and prior allows a remote attacker to cause a denial-of-service (DoS) condition in the affected product by rapidly establishing a large number of TCP connections to it, resulting in an inconsistency in the product's internal connection management process and triggering improper memory access.

First published (updated )
Severity
8.7
EPSS
0.64%
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Expected Behavior Violation vulnerability in Mitsubishi Electric MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP all versions allows a remote attacker to cause a denial-of-service (DoS) condition in the affected product by continuously sending a large number of communication packets to the Ethernet port of the product in a short period of time, increasing the processing load of the product, preventing the internal anomaly-detection processing from being performed, and causing the communication function to stop.

First published (updated )
Severity
7.2
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Room Air Conditioners (for Japan and outside Japan); Wireless LAN Adapters for Room Air Conditioners (for Japan and outside Japan); Wireless LAN Adapters for Packaged Air Conditioners (for Japan and outside Japan); Refrigerators (for Japan); Heat Pump Water Heaters / HEMS-Compatible Adapters / Wireless LAN Adapters (for Japan); Bathroom Dryer / Heater / Ventilation Systems (for Japan); Adapters for Airflow Ventilation Systems, Heat Pump Chilled / Hot Water Systems, and Ventilation / Air-Conditioning System Air Resorts (for Japan); Lossnay Central Ventilation Systems (for Japan); Smart Switches for Ventilation Fans and Lossnay (for Japan); IH Cooking Heaters (for Japan); and Rice Cookers (for Japan) allows an attacker within Wi-Fi radio range of an affected product to access the affected product using a hard-coded SSID and password, thereby obtaining device data such as operation status, room set temperature, and room temperature; changing the air-conditioner or Wi-Fi settings; or causing Wi-Fi communication to enter a denial-of-service (DoS) condition.

First published (updated )
Severity
4
EPSS
0.01%
AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:H/A:N

Windows Shortcut Following (.LNK) vulnerability in multiple processes of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric GENESIS version 11.00, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95, and Mitsubishi Electric Iconics Digital Solutions GENESIS version 11.00 allows a local authenticated attacker to make an unauthorized write to arbitrary files, by creating a symbolic link from a file used as a write destination by the processes of the affected products to a target file. This could allow the attacker to destroy the file on a PC with the affected products installed, resulting in a denial-of-service (DoS) condition on the PC if the destroyed file is necessary for the operation of the PC.

First published (updated )
Severity
8.7
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Always-Incorrect Control Flow Implementation vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP versions 1.106 and prior and Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP versions 1.000 and prior allows a remote attacker to cause a denial-of-service (DoS) condition on the products by continuously sending UDP packets to the products. A system reset of the product is required for recovery.

First published (updated )
Severity
8.7
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Improper Resource Shutdown or Release vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP all versions allows a remote attacker to cause a denial-of-service (DoS) condition on the products by continuously sending UDP packets to the products. A system reset of the product is required for recovery.

First published (updated )
Severity
8.7
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Improper Resource Shutdown or Release vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP versions 1.000 and prior allows a remote attacker to cause a denial-of-service (DoS) condition on the products by continuously sending UDP packets to the products. A system reset of the product is required for recovery.

First published (updated )
Severity
5.3
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L

Insufficient Resource Pool vulnerability in Ethernet function of Mitsubishi Electric Corporation MELSEC iQ-R series CPU module, MELSEC iQ-L series CPU module, MELSEC iQ-R Ethernet Interface Module, MELSEC iQ-R CC-Link IE TSN Master/Local Module, CC-Link IE TSN Remote I/O Module, CC-Link IE TSN Analog-Digital Converter Module, CC-Link IE TSN Digital-Analog Converter Module, CC-Link IE TSN - CC-Link IE Field Network Bridge Module, CC-Link IE TSN - AnyWireASLINK Bridge Module, CC-Link IE TSN FPGA Module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Motion Module, MELSEC iQ-L Motion Module, MELSEC iQ-F FX5 Motion Module, MELSEC iQ-F Series CPU module, MELSEC iQ-F Series Ethernet module, MELSEC iQ-F Series Ethernet/IP module, MELSEC iQ-F Series OPC UA Module, MELSEC iQ-F Series CC-Link IE TSN master/local module, GOT2000 Series CC-Link IE TSN Communication Unit, FR-A800-E series inverters, FR-F800-E series inverters, FR-E800-E series inverters, INVERTER CC-Link IE TSN Plug-in option, INVERTER CC-Link IE TSN Safety Plug-in option, INVERTER CC-Link IE TSN communication function built-in type, MR-J5 series AC Servos MELSERVO, MR-JET series AC Servos MELSERVO, MR-MD333G series AC Servos MELSERVO, MR-JE series AC Servos MELSERVO, MELSERVO-J4 AC Servos MELSERVO and Embedded Type Servo System Controller allow a remote attacker to cause a temporary Denial of Service condition for a certain period of time in Ethernet communication of the products by performing TCP SYN Flood attack.

First published (updated )
Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Incorrect Pointer Scaling vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series and MELSEC-L Series CPU modules allows a remote unauthenticated attacker to read arbitrary information from a target product or execute malicious code on a target product by sending a specially crafted packet.

First published (updated )
Severity
9.8
Integer Overflow
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Integer Overflow or Wraparound vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series and MELSEC-L Series CPU modules allows a remote unauthenticated attacker to execute malicious code on a target product by sending a specially crafted packet.

First published (updated )
Severity
9.8
Integer Overflow
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Integer Overflow or Wraparound vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series and MELSEC-L Series CPU modules allows a remote unauthenticated attacker to execute malicious code on a target product by sending a specially crafted packet.

First published (updated )
Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Incorrect Pointer Scaling vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series and MELSEC-L Series CPU modules allows a remote unauthenticated attacker to execute malicious code on a target product by sending a specially crafted packet.

First published (updated )
Severity
9.8
Integer Overflow
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Integer Overflow or Wraparound vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series and MELSEC-L Series CPU modules allows a remote unauthenticated attacker to execute malicious code on a target product by sending a specially crafted packet.

First published (updated )
Severity
4
AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:N

Execution with Unnecessary Privileges vulnerability in multiple services of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric BizViz all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS versions 11.00, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95, Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions, Mitsubishi Electric Iconics Digital Solutions BizViz all versions, and Mitsubishi Electric Iconics Digital Solutions GENESIS versions 11.00 allows a local authenticated attacker to make an unauthorized write to arbitrary files, by creating a symbolic link from a file used as a write destination by the services of the affected products to a target file. This could allow the attacker to destroy the file on a PC with the affected products installed, resulting in a denial-of-service (DoS) condition on the PC if the destroyed file is necessary for the operation of the PC.

First published (updated )
Severity
5.9
AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N

Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in.

First published (updated )
Severity
7.8
AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or to cause a denial of service (DoS) condition on the products.

First published (updated )
Severity
7.8
EPSS
0.04%
AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products.

First published (updated )
Severity
7
AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H

Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior allows a local attacker to execute a malicious code by storing a specially crafted DLL in a specific folder when GENESIS64, ICONICS Suite, Hyper Historian, GENESIS32, and MC Works64 are installed with the Pager agent in the alarm multi-agent notification feature.

First published (updated )
Severity
6.7
AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H

Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in the licensing feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric BizViz versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions BizViz versions 9.7 and prior allows a local attacker to execute a malicious code with administrative privileges by tampering with a specific file that is not protected by the system.

First published (updated )
Severity
7.5
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Improper Validation of Specified Type of Input vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET versions 1.100 to 1.200 and FX5-ENET/IP versions 1.100 to 1.104 allows a remote attacker to cause a Denial of Service condition in Ethernet communication of the products by sending specially crafted SLMP packets.

First published (updated )
Severity
8.8
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric MELSEC iQ-R Series R08PCPU, R16PCPU, R32PCPU, and R120PCPU allows an unauthenticated attacker to read device data or part of a control program from the affected product, write device data in the affected product, or cause a denial of service (DoS) condition on the affected product by sending a specially crafted packet containing a specific command to the affected product.

First published (updated )
Severity
8.8
AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H

Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation FREQSHIP-mini for Windows versions 8.0.0 to 8.0.2 allows a local attacker to execute arbitrary code with system privileges by replacing service executable files (EXE) or DLLs in the installation directory with specially crafted files. As a result, the attacker may be able to disclose, tamper with, delete, or destroy information stored on the PC where the affected product is installed, or cause a Denial of Service (DoS) condition on the affected system.

First published (updated )
Severity
7
AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H

Dead Code vulnerability in Mitsubishi Electric GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric Iconics Digital Solutions GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, and Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3 allows a local authenticated attacker to execute a malicious code by tampering with a specially crafted DLL. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products.

First published (updated )
Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.